Verification Case 4

View Model     Problem Statement

PRODUCT: AFT Fathom

TITLE: FthVerify4.fth

REFERENCE: D.S. Miller, Internal Flow Systems, 2nd Ed., 1990, Gulf Publishing Co., Page 197-199

FLUID: Air

ASSUMPTIONS: Air is incompressible

RESULTS:

Parameter Miller AFT Fathom
System head loss (m of air) 40.3 40.36
System head loss (mm of water) 49.6 49.64

DISCUSSION:

The velocity and diameter are specified. For use in AFT Fathom, this is converted to a flow rate, obtaining 0.8 m3/sec.

The head loss in the pipe in AFT Fathom can be easily obtained from the pipe dP Stag and dH output values.