Verification Case 75
PRODUCT: AFT Fathom (with SSL Module)
TITLE:
REFERENCE: Wilson, Addie, Sellgren & Clift, Slurry Transport Using Centrifugal Pumps 3rd Edition, 2006, Publisher Springer, Pages 329-337, Case Study 13.1
FLUID: Water/Sand
ASSUMPTIONS: Water temperature is assumed to be 4 deg. C. Other than the pipe diameter, the system configuration is not given (i.e. pressures, pipe length, etc) and were assumed. These assumptions do not affect the final results of the problem. Assume Vt/Vts = 0.56 for sand.
RESULTS: