The following pipes have vapor volumes in computing stations greater than 0.1% but less than 10% of the liquid computing volume
A Caution message in AFT Impulse
Full Message Text
The following pipes have vapor volumes in computing stations greater than 0.1% but less than 10% of the liquid computing volume:
Pipe X (Name), Stations: Y (Z%)
Explanation
This Caution is part of a series of Output Messages meant to convey increasing uncertainty in results as Percent Vapor Volume increases.
-
Caution - greater than 0.1% but less than 10%
-
Warning - greater than 10% but less than 100%
-
Critical Warning - greater than 100%
A detailed explanation about the Percent Vapor Volume parameter, section volume, and assumptions can be found on the Interpreting Cavitation Predictions topic. In summary, Impulse's solution methodology assumes that pipe sections are 100% liquid-full. This warning is stating that for the listed pipe stations, the Percent Vapor Volume was greater than 0.1% but less than 10% of the section volume at some point during the transient, which is violating the 100% liquid-full assumption to a minor degree.
Vapor volumes between 0.1 and 10% of the section volume indicate that limited transient cavitation is occurring at that point in the system. Impulse's cavitation models are meant to capture limited transient cavitation in a system, and have limited accuracy as vapor volume increases. Depending on the system, this amount of transient cavitation may be a cause for concern since it can lead to additional waterhammer effects.
Required Action
Users should explore the various cavitation topics - and in particular the Interpreting Cavitation Predictions topic - to better understand what is causing these results, why they are possible, and how to interpret results in scenarios seeing this caution. If all else fails, users should treat systems with these results with caution, and incorporate additional safety factors into their designs.