Entering Reservoir Transient Data
Infinite Reservoirs
For an infinite reservoir, the liquid level or surface pressure can be varied over time according to a user specified transient profile (see Table 1 in the Entering Reservoir Volume Data topic). This is input on the Transient tab (see Figure 1).
Figure 1: Infinite reservoirs can have user specified time varying liquid level or surface pressure
Finite Open Tanks
For a finite open tank, the surface pressure can be varied over time according to a user specified transient profile. This is input on the Transient tab (Figure 2).
Finite Closed Tanks
For a finite closed tank with a maximum allowable pressure (this is a relief pressure), the relief pressure can be varied over time according to a user specified transient profile. This is input on the Transient tab.
Figure 2: Finite tanks can have user specified time varying surface pressure