Verification Case 21
PRODUCT: AFT Fathom
TITLE: FthVerify21.fth
REFERENCE: Igor Karassik, William Krutzsch, Warren Fraser, Joseph Messina, Pump Handbook, 2nd Ed., 1986, McGraw-Hill, Page 8.38, Example 9
FLUID: Water, using Hazen-Williams
ASSUMPTIONS: N/A
RESULTS:
Parameter | Handbook | AFT Fathom |
Head loss (feet) | 4.8 | 4.8 |
DISCUSSION:
Results for AFT Fathom vary somewhat from previous versions of AFT Fathom (prior to version 7) because the equation used to convert the Hazen-Williams factor to the Darcy-Weisbach friction factor was modified to use the traditional formula, as given in the AFT Fathom help file.