Verification Case 42

View Model     Problem Statement

PRODUCT: AFT Fathom

TITLE: FthVerify42.fth

REFERENCE: Theodore Baumeister, Eugene Avallone, Theodore Baumeister III, Marks’ Standard Handbook for Mechanical Engineers, 8th ed., 1978, McGraw-Hill, Page 3-58

FLUID: Water at 68 deg. F

ASSUMPTIONS: Area change elevation is 130 feet, tanks are 10 feet deep

RESULTS:

Parameter Marks' AFT Fathom
Flow rate (ft3/sec) 0.4143 0.4144

DISCUSSION:

The fitting K factors were included in the pipes as a fitting and loss value.

List of All Verification Models