Verification Case 77

View Model     Problem Statement

PRODUCT: AFT Fathom (with ANS Module)

TITLE: FthVerify77.fth

REFERENCE: William S. Janna, Introduction to Fluid Mechanics, 1983, PWS Publishers, Example 5.8, pages 179-180.

FLUID: Methanol

ASSUMPTIONS: N/A

RESULTS:


Janna AFT Fathom
Minimum Diameter 6.338 cm 6.337 cm
Nominal Size 2-1/2 in 2-1/2 in

DISCUSSION:

The AFT Fathom model used an assigned pressure upstream and a receiving reservoir at atmospheric pressure. The only design requirement for the system was a minimum flow rate of 0.8 m3/min.

The automated sizing was a discrete sizing to minimize flow volume.