Verification Case 26
PRODUCT: AFT Fathom
TITLE:
REFERENCE: Michael R. Lindeburg, P.E., Mechanical Engineering Review Manual, 7th Ed., Professional Publications, Page 4-6, Example 4.1
FLUID: Water
ASSUMPTIONS: N/A
RESULTS:
Parameter | Lindenburg | AFT Fathom |
NPSHA (feet) | 50.7 | 50.69 |
Total suction head (feet) | Not given | 18.38 |
DISCUSSION:
The NPSHA is given in the AFT Fathom Pump Summary of the Output window.
Note this model uses fluid properties from the AFT Standard fluid library. The AFT Standard fluid library was updated in AFT Fathom 12, thus the AFT Fathom results will be slightly different for this verification case when compared to previous versions of AFT Fathom.