Verification Case 41

View Model     Problem Statement

PRODUCT: AFT Fathom

TITLE: FthVerify41.fth

REFERENCE: Robert W. Fox and Alan T. McDonald, Introduction to Fluid Mechanics, 3rd Ed., 1985, John Wiley & Sons, Page 385-389, example 8.11

FLUID: Water at 60 deg. F

ASSUMPTIONS: N/A

RESULTS:

Parameter Fox & McDonald AFT Fathom
Flow rate to Branch 1 (gal/min) 493 493.48
Flow rate to Branch 2 (gal/min) 557 557.44
Flow rate to Branch 3 (gal/min) 449 449.09
Pressure at inlet (psig) 91.2 91.52

DISCUSSION:

Fox and McDonald use equivalent lengths to model the elbows. These were converted to K factors of 0.4 in AFT Fathom. The loss factors at the three sprays (modeled as assigned pressure junctions) were specified as 16. This allows for the area ratio of 2 to the 4th power to account for the energy lost at the discharge.

Note this model uses fluid properties from the AFT Standard fluid library. The AFT Standard fluid library was updated in AFT Fathom 12, thus the AFT Fathom results will be slightly different for this verification case when compared to previous versions of AFT Fathom.

List of All Verification Models