Verification Case 55

View Model     Problem Statement

PRODUCT: AFT Fathom

TITLE: FthVerify55.fth

REFERENCE: William S. Janna, Introduction to Fluid Mechanics, 1983, PWS Publishers, Page 189-190, Example 5.10

FLUID: Water

ASSUMPTIONS: Water at 75 deg. F

RESULTS:

Parameter Janna AFT Fathom
Pump ideal power (hp) 0.737 0.733

DISCUSSION:

The losses due to elbows are included as a fitting and loss value in the pipes. The ideal power usage is given the Output window Pump Summary.

List of All Verification Models