Optional Input for Junctions
Initial Guesses
A user defined initial guess can be entered for pressure (or head) and temperature for most junctions. This is only an initial guess for the Solver - the solution will vary from this value, and the value has no effect on the end solution.
A good initial guess can be helpful to decrease the number of Solver iterations required.
Display on Workspace
By default, only the junction number is displayed on the Workspace. In addition to this, the junction name can be displayed.
Special Conditions
The Special Condition can be changed for some junctions. For example, a valve can be set to closed, preventing all flow. A symbol (default of "X") will be placed before the junction label indicating that a special condition is applied.
Design Factor
A design factor can be used to add safety margins into the analysis. For junctions, three types of design factors exist:
-
Compressor/Fan Junctions: head rise at the compressor/fan is multiplied by the design factor assigned to the compressor/fan.
-
Heat Exchanger Junctions: total rate of heat transfer is multiplied by the Heat Transfer design factor assigned to the heat exchanger. The total loss factor is multiplied by the Friction Loss design factor assigned to the heat exchanger.
-
All other junctions: total loss factor is multiplied by the design factor assigned to the junction.
Note: The design factor for compressors/fans has the opposite effect on a system that the design factor for other junction types has. A design factor of 1.1 for junctions with a pressure loss will give an extra 10% pressure drop at that junction, adding resistance to the system. A design factor of 1.1 for the compressor/fan junction will give an extra 10% pressure rise, effectively modeling the compressor/fan as having extra capacity than expected. To add a 10% safety margin to the compressor junction, a design factor of 0.9 should be used.
Workspace Icon
You may want to change the icon to better represent a specific junction type. This is accomplished by clicking the Change Icon button. The size of the junction can also be changed here.