Engineering Assumptions

AFT Arrow is based on the following fundamental fluid mechanics assumptions:

  • Compressible flow

  • Steady-state conditions (the XTS Module allows transient modeling through steady-state snapshots)

  • One-dimensional flow

  • System is fluid-full

  • All gases are superheated (single phase)

  • No chemical reactions

  • No supersonic flow in the system