Summary of Verification Models with Pumps

Summary of All Verification Models

Comparison of AFT Fathom predictions for pumped systems to the published calculation results.

Case Fluid Pipes Pumps NPSH PRV’s Reference
Case 3 Water 2 1 No 0 Miller
Case 11 Water 8 1 No 0 Brater, Williams, Lindell and Wei
Case 12 Water 3 1 Yes 0 Ingersoll-Dresser Pumps
Case 13 Water 3 1 Yes 0 Ingersoll-Dresser Pumps
Case 14 Water 3 1 Yes 0 Ingersoll-Dresser Pumps
Case 15 Water 3 1 Yes 0 Ingersoll-Dresser Pumps
Case 16 Water 3 1 Yes 0 Ingersoll-Dresser Pumps
Case 17 Water 2 1 No 0 Ingersoll-Dresser Pumps
Case 18 Specific gravity = 0.8 2 1 No 0 Karassik, Krutzsch, Fraser and Messina
Case 23 Viscous Fluid 2 1 No 0 Hydraulic Institute
Case 26 Water 8 1 Yes 0 Lindeburg
Case 55 Water 2 1 No 0 Janna
Case 58 Water 6 3 No 0 Chopey
Case 59 Water 10 3 No 0 Jeppson
Case 60 Water 9 1 No 1 Jeppson
Case 61 Water 17 1 No 0 Jeppson
Case 63 Water 8 1 No 0 Jeppson
Case 64 Water 10 1 No 1 Jeppson
Case 66 Water 16 1 No 1 Jeppson
Case 67 Water 31 3 No 0 Jeppson
Case 68 Water 68 5 No 0 Jeppson
Case 69 Water 70 5 No 0 Jeppson